 M 8 3 5 0  Series PLS Modules

 S P E C I F I C A T  I O N S

PLC Plug-in Modules

PLC COMMUNICATION:

Slots: . . . . . . . . . . . . . . .  . one
I/O Addresses: . . .  . . 4 In/4 Out

POWER REQUIREMENTS:
Backplane:
5 VDC @ 650 mA
Customer (Power Input):
24 VDC ± 15% @ 100 mA

ENVIRONMENTAL CONDITIONS:

Operating temperature:
-10 to +130 °F (-23 to +55 °C)
Relative humidity:
5 to 95% noncondensing

RESOLVER INTERFACE:

Position transducer:
Resolver, Autotech Series RL100 or E7R
Resolver cable:
Overall foil shielded, twisted-pair, such as Autotech's cable:
CBL-10T22-xxxx
Cable length between resolver and M8350:
2,500 ft. (762 m) max, shielded

PROGRAMMING:

All features programmable from keypad or through backplane.
Scale factor:
Programmable from 19 to 4,095
(resolution 20 to 4,096 counts/turn)

[cont >>>]

Offset:
Programmable from zero to scale factor value
Fault detector:
TRUE (active) on power up. FALSE if broken resolver wire or internal fault is  detected.
Motion detector:
Low and high motion limits are programmable from zero to 1,999 RPM. Motion detector is TRUE when the machine's RPM is within the programmed limits. Motion detector's  status is available on the backplane.

RESPONSE TIMES:
Tach update time: 15 msec.
Position, tach, and output status available to backplane:
Every 700 µsec., typical

CONTROL INPUTS:

Program Enable (PE):
PE must be TRUE for setup programming
Output Enable (OE):
OE must be TRUE for outputs to be enabled (applies only when optional ASY- M8250-NOUT module is used)

ELECTRICAL SPECIFICATIONS

(All Inputs):
Optical isolation:
2,500 VAC RMS
Input current:
3 mA, typical @ 24 VDC
Logic levels:
TRUE: 21 to 27 VDC (V+ relative to V-) (not to exceed) FALSE: <1 VDC