CARD LOCATION: Uses one slot PLC rack
PLC COMMUNICATION:
Through input and output registers; allocate 12 Input and 12 Output registers for Modicon 984 Compact, 6 IN, 6 OUT for TSX Quantum
POWER REQUIREMENTS:
Customer (Power Input): 24 VDC ± 15% @ 100 mA Position Transducer: Resolver, Autotech Series RL100 or E7R Motion Detector: Programmable Low and High limits, 0-999 RPM Brake Monitor: Programmable Caution and Danger Limits zero to 9.99 sec. max. Fault Output: Normally energized. Deenergizes if broken resolver wire or internal fault is detected. Motion Output: Output energized whenever resolver RPM is between programmed limits.
|
RESOLVER INTERFACE:
Position transducer: Resolver; Autotech Series RL100 or E7R. Cable length between resolver and M8350: 2,500 ft (762 m) max, shielded Resolver cable: Overall foil shielded, twisted-pair, such as Autotech's cable (CBL-10T22-xxxx)
M7251PLS MODULE
PLS Outputs : . . . . . . . . . . . . 16 PLS setpoints : 112 per PLS setup (maximum of 56 per group of 8 outputs) No. of Setups : . . . . . . . . . eight Speed Compensation : Each PLS output has it's own compensation. Leading-Edge and Trailing-Edge speed compensation available. |